When a new LSR mold is ready for acceptance, most buyers focus on one question: did the first article samples pass dimensional inspection? If the report shows "Pass" next to every dimension, it's easy to sign off and move to production. But a passing first article report and a mold that will run reliably for the life of an order are not the same thing — and the difference usually shows up in three data points that get far less attention than the pass/fail column.
A dimension can measure well within tolerance on a single first-article sample and still come from a process that isn't stable enough to stay there run after run. This is exactly what Cpk is designed to catch, and it's the single most important number in an SPC report that buyers commonly skip past.
What to ask for: request the Cpk value for every critical-to-function dimension, not just the raw measurement of a single sample, and ask what sample size and sampling method were used to calculate it.
A first article report is only as meaningful as the conditions under which it was collected, and this context is frequently left out of the summary page buyers actually read.
What to ask for: a clear statement of sample size per cavity, and confirmation that samples were taken at production-representative cycle conditions, not an artificially slowed-down qualification run.
An SPC report that shows only average, minimum, and maximum values for a dimension can hide a trend that matters more than any single statistic: is the dimension drifting in one direction over the course of the run?
What to ask for: the raw run chart or control chart for critical dimensions, not just the summary average — and ask the mold maker to flag any dimension showing a directional trend, even if it's still technically within tolerance.
Liquid silicone parts tend to have tighter functional tolerances relative to their nominal size than many rigid plastic parts — particularly for sealing surfaces, medical components, and precision consumer electronics parts — which means a process with marginal Cpk or an undetected trend is more likely to produce a real functional failure, not just a cosmetic one.
Before signing off on a new mold based on its first article report, it's worth confirming:
A first article report that includes this level of detail is usually a sign of a mold supplier who understands that "passing" and "production-ready" are two different standards — and that the gap between them is exactly what a thorough SPC report is meant to close.